Evaluation of the surface nanoscale changes of R-phase, M-wire nickel-titanium instruments after use in extracted molars: An in vitro study


Department of Restorative Dental Sciences, College of Dentistry, Taibah University, Al Madinah Al Munawarah, Saudi Arabia

Correspondence Address:
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sej.sej_18_20

Rights and Permissions

Introduction: The objective was to explore the impact of root canal instrumentation on the surface nanoscale characteristics of M-wire (ProTaper Next®[PTN]) and R-phase (twisted file [TF]) nickel–titanium (NiTi) instruments. Materials and Methods: Endodontic cleaning and shaping was performed on the curved canals of the mesial roots of mandibular extracted molars (n = 32). Canal curvatures ranged from 20° to 30° according to the Schneider method. PTN and TF NiTi instruments were used for this purpose. The surface parameters of NiTi instruments were evaluated before and after the root canal instrumentation using a Dektak three-dimensional nanoscale surface profiler. An analysis of variance and Student's t-test were used to determine the significance of various parameters of the NiTi instruments before and after the root canal instrumentation. The statistical significance level was set at P < 0.05. Results: There were no significant differences in the root mean square roughness (Sq), average roughness value (Sa), and peak to valley height (Sz) in flutes between the instruments (P > 0.05) or in the Sq in blade location. However, the Sa and Sz in blade location were significantly greater for TF than PTN. The TF instruments had greater surface roughness than PTN. The PTN instruments exhibited minor surface cracks, while TF instruments exhibited cracks and microcavities. Conclusion: Endodontic instrumentation altered the surface characteristics; the surface distortion was significantly greater for the TF instruments than the PTN instruments.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed686    
    Printed40    
    Emailed0    
    PDF Downloaded146    
    Comments [Add]    

Recommend this journal